County guides / Dún Laoghaire-Rathdown
Dún Laoghaire-Rathdown · county guide
Dún Laoghaire-Rathdown's rules for one-off rural houses come from the Dún Laoghaire-Rathdown County Development Plan 2022–2028, which divides the county into 4 rural area types. It lists 6 local-need categories, and none of the area types in the extract is described as exempt from the local-need test. A grant carries a 7-year occupancy condition (Section 12.3.10.3).
01 · Area types
PHP23
Dwellings on suitable sites where the applicant shows either a genuine need to live near rural-community employment, or a genuine need for an additional rural dwelling as a native of the area (substantial past residence and close family ties) per Section 3.2.3 of the 2005 Guidelines.
PHP23
Dwellings only where principal employment is in agriculture, hill farming or a local enterprise tied to the area's amenity potential, with no negative impact on visual prominence, views or natural/built heritage.
PHP24 · CS5
Residential development restricted; genuine need to live in the green belt required, minimum 4 hectares per individual dwelling, open character maintained, and no undermining of a Strategic Land Reserve (CS5 applies where overlapping).
PHP23
2007 and 2013 Glencullen LAP criteria apply until a new LAP is made; Glencullen Design Guide principles apply elsewhere in rural areas.
Map: Development Plan zoning maps (Objectives B, G and Green Belt / Strategic Land Reserve); confirm the site's zoning; the engine cannot read the maps.
02 · Local need
03 · Condition of permission
Section 47 agreement normally required restricting occupation for 7 years to the applicant or other persons agreed by the Planning Authority.
04 · Development management
| Standard | What the plan says | Policy |
|---|---|---|
| Chapter 4 — Neighbourhood: People, Homes and Place, Policy Objectives PHP23 (Management of One-off Housing) and PHP24 (Housing in Green Belt Areas); Chapter 12 Section 12.3.10 | ||
| Site size | Green Belt only — minimum 4 hectares per individual dwelling; no minimum stated for Objective B or G lands. | PHP24 |
| Ribbon development | Plan states "Suburban-type and/or ribbon development is not acceptable in rural areas"; dwellings generally set well back from the road. No numeric definition. | Section 12.3.10.2 |
| Sightlines | Satisfactory capacity of the access road/lane, suitable vehicular access, adequate parking and manoeuvring; no sightline distances stated. | Section 12.3.10.1 |
| Access | No national/regional-road rule in the rural housing sections. | |
| Wastewater | Site suitability report for wastewater treatment required; site must accommodate a treatment system. EPA Code of Practice not cited in these sections. | Section 12.3.10 / 12.3.10.1 |
| Roadside boundary | Traditional field pattern preserved; roadside and field boundary hedges retained and/or reinstated; recessed gateways in local materials and an indigenous style. | Section 12.3.10.2 |
| Replacement dwellings | Replacement Dwelling – Rural standards apply (content not extracted). | Section 12.3.10.4 |
| Chapter 12 — Development Management (12.3.10 Rural Dwellings, 12.4.8 Vehicular Entrances, 12.10.3 Waste Water Treatment Systems) | ||
| Site size | No minimum site area stated; site must be able to accommodate the dwelling, a water supply (borehole) and a wastewater treatment system (12.3.10.1). Individual new houses generally require a minimum road frontage of 'at least 60 metres' (12.3.10.7). In high–extreme groundwater vulnerability areas (Rathmichael, Kiltiernan, Glencullen) further hydrogeological assessment is triggered where development 'results in a density of higher than 6 per hectare' (12.10.3.1). | 12.3.10.1 / 12.3.10.7 / 12.10.3.1 |
| Sightlines | No numeric table. 12.3.10.8: 'adequate sight distances in both directions' having regard to traffic and road characteristics; 12.4.8.1: driveway exit sightlines to DMURS appropriate to road type and speed. | 12.3.10.8 / 12.4.8.1 |
| Entrance | 'Vehicular entrance gates shall be recessed', with wing walls or fences splayed (12.3.10.8); 'Recessed gateways should be constructed in local materials and in a style indigenous to the area' (12.3.10.2); no set-back distance given. Electronic gates unacceptable unless set back from the back of the footway; outward-opening gates generally not permitted (12.4.8.1). | 12.3.10.8 / 12.3.10.2 / 12.4.8.1 |
| Wastewater | Site assessment and design to the EPA Code of Practice for single-house systems and Environmental Health Office requirements; a detailed site investigation report with percolation and water table tests certified by a qualified person to accompany the application, with a trial hole available for inspection (12.3.10.9). Systems not on public sewer 'subject to full compliance with the EPA Code of Practice Domestic Wastewater Treatment Systems' (p.e. ≤10); site suitability assessment required; 'Wastewater treatment systems shall be located entirely within the site boundary' (12.10.3.1). No county-specific separation distances. | 12.3.10.9 / 12.10.3.1 |
| Boundary | 'roadside and field boundary hedges retained and/ or reinstated'; native tree planting scheme required; dwellings set well back from the road (12.3.10.2). | 12.3.10.2 |
Design guide: None adopted — plan commits to producing a rural design guide (possibly within a Glencullen LAP); interim guidance in 12.3.10.2
05 · Refusals
06 · Your site
The guide above is the policy. The report applies it to one site: which area type it falls in, every application nearby and how it went, flood, ground and designations, with every source linked.
07 · Source
Extracted from the adopted plan. Read directly from the adopted Chapter 4 and Chapter 12 PDFs on dlrcoco.ie; the plan sets no residence-years or km thresholds and no minimum site size outside the Green Belt.