County guides / Longford
Longford · county guide
Longford's rules for one-off rural houses come from the Longford County Development Plan 2021–2027 (Volume 1), which divides the county into 4 rural area types. It lists 5 local-need categories, and describes Rural Areas Elsewhere as not requiring a local-need test. A grant carries a 7-year occupancy condition (CPO 4.28 (Section 47 agreement)).
01 · Area types
CPO 4.24
Environs and commuting catchments of the county's large towns. Single houses only for applicants meeting all five CPO 4.24 criteria (local rural area, functional requirement, no prior countryside house, no alternative outside Areas of Special Control, high-quality design).
CPO 4.26 · CPO 4.27
Residual rural areas (strong and structurally weak). Local housing need does not apply; assessed on siting, design and negligible impact on amenities or sensitive environments.
CPO 4.24 criterion 4
Where the site is in an Area of Special Control the applicant must show no alternative site exists outside it.
CPO 4.39
Housing for established families only, strictly controlled; the Canal is also an NHA.
Map: Figure 4.5 Rural Typology Map County Longford (Volume 1, based on Electoral Divisions). Confirm the site's typology.
02 · Local need
03 · Condition of permission
In Rural Areas Under Strong Urban Influence, use restricted to the applicant as permanent residence for 7 years from first occupation. Replacement of a derelict dwelling (CPO 4.43) also carries an occupancy condition.
04 · Development management
| Standard | What the plan says | Policy |
|---|---|---|
| Chapter 4 — 4.8.12 Rural Settlement Strategy, CPO 4.24–4.45 Rural Housing County Policy Objectives | ||
| Site size | Not stated in Chapter 4; see Chapter 16 (not yet read). | Chapter 16 Development Management Standards |
| Ribbon development | Ribbon = five or more houses alongside 250 m of road frontage; assessed on area type, infill degree, coalescence and local planning history. Special regard for immediate family of a landowner on a single infill site in an existing ribbon. | CPO 4.32 |
| Cluster | Recessed clusters of up to five houses set back from the road considered, subject to local need. | CPO 4.33 / 4.37 |
| Backland sites | Backland sites for family members only; single-storey (attic allowed), independent percolation area, screening in place before occupation. | CPO 4.34 |
| Access | New accesses for one-off dwellings restricted onto regional roads where the 80 km/h limit applies; national-road access per Section 5.2.3 and the Spatial Planning and National Roads Guidelines. | CPO 4.38; CPO 5.17 / 5.19 |
| Sightlines | Safe access required (CPO 4.35 b); numeric sightlines in Chapter 16 (not yet read). | Chapter 16 |
| Wastewater | EPA Code of Practice site suitability tests; septic tanks and package systems with Irish Agrément certification. | CPO 4.35 |
| Entrance and boundary | Rural-style entrances with native double-row hedgerow on a sod/earth mound; high block walls, gates and ornamental features not permitted. | CPO 4.40 |
| Speculative landholding | Development restricted on a landholding with a history of speculative site sales, even where the applicant meets local need. | CPO 4.29 |
| Replacement dwellings | Vernacular restoration not subject to the rural strategy; replacing a habitable non-vernacular house on the same footprint needs no local need; a derelict replacement is treated as new. | CPO 4.41–4.43 |
| Chapter 16 — Development Management Standards (16.4.5.7 Rural Housing DMS 16.88–16.93, p. 427; 16.4.7 Roads and Access DMS 16.114–16.116) | ||
| Site size | DMS 16.92(a): 'The minimum acceptable site size for a dwelling using an individual treatment system (septic tank and percolation area or equivalent) is 0.2ha.' The figure rises where neighbouring systems exist or percolation results are borderline (upper or lower 20% of permitted limits). | DMS 16.92(a) |
| Sightlines | DMS 16.114: 'Safe unobstructed sight distances should be provided and maintained thereafter from vehicular entrances onto the road network as follows:' (speed limit — National Primary / National Secondary / Regional / Local; standard): 120 km/h 295 m / 295 m / – / – (TII Publications); 100 km/h 215 m / 215 m / 215 m / – (TII); 80 km/h 160 m / 160 m / 160 m / 160 m (TII; Local 'desirable but subject to road width and alignment, traffic volumes and traffic speeds', lesser distance at the Planning Authority's discretion where shown adequate); 60 km/h 65 m all roads (DMURS); 50 km/h 49 m; 40 km/h 36 m; 30 km/h 24 m (DMURS). Figure 15.2 Calculating Sightlines: 'x Distance = 3.0m Visability Splay'. | DMS 16.114 / Figure 15.2 |
| Entrance | No gate set-back figure. DMS 16.93(e): 'The design of entrance gates should be in keeping with the rural setting'; entrances, wing walls and piers not in character with the rural location generally not permitted. DMS 16.115: minimum building lines from the road 35 m National Primary/Secondary, 25 m Regional, 15 m Local; 16.115(a) 'In general, only the minimum interference with existing roadside boundaries and hedges shall be permitted.' DMS 16.116: 'New rural entrances should not be located within the following distances of junctions' — National Primary 150 m, National Secondary 100 m, Regional 100 m, Local 40 m. | DMS 16.93(e) / DMS 16.115 / DMS 16.116 |
| Wastewater | DMS 16.92(b): 'The applicant shall submit details of the proposed effluent treatment system' in accordance with the EPA wastewater treatment manual (or update); (c) 'Where a treatment system is to be installed, the applicant shall submit full site-specific details' certified by a suitably qualified, indemnified person, with Irish Agrément Board and manufacturer's site-suitability certification and a five-year maintenance agreement before first occupancy; (d) Council to 'investigate the establishment of a panel of assessors for the submission of site assessments'. Treatment type: septic tank and percolation area or equivalent. No separation distances stated by the county. | DMS 16.92(b)–(d) |
| Boundary | DMS 16.93: (a) 'Application sites should be flanked with a minimum of two established natural boundaries'; (b) 'Existing hedgerows and landscape features on site should be retained and augmented on site' — where hedgerow must be removed for sight lines, native hedging planted inside the line of visibility; (c) 'New roadside frontage should be incorporated into existing roadside treatment' using compatible hedging, walls, timber fencing or drystone work; (d) 'Boundary treatment should reflect local traditions' — drystone or lime-mortared limestone walls, or post-and-wire/timber fencing back-planted with indigenous hedging at entrances, over-scaled designs avoided. 16.4.7: 'Existing roadside hedgerows and trees should be retained as much as possible', sight distance achieved 'with the removal of a minimum extent of existing hedgerow'. | DMS 16.93(a)–(d) / 16.4.7 |
Design guide: None named in Chapter 16 (16.4.5.7 relies on DMS 16.88–16.89 design criteria and Chapter 4); Annex 7 Rural Design Guidance sits in Volume 3
05 · Refusals
06 · Your site
The guide above is the policy. The report applies it to one site: which area type it falls in, every application nearby and how it went, flood, ground and designations, with every source linked.
07 · Source
Extracted from the adopted plan. Read verbatim from the adopted Volume 1 PDF (pp. 100–108 of the plan) via browser. Chapter 16 development management standards (site size, sightlines) and Annex 7 Rural Design Guidance not yet read. Note the printed CPO numbers sit in a margin column; the pairing below follows the order of the objectives on the page.