County guides / Carlow
Carlow · county guide
Carlow's rules for one-off rural houses come from the Carlow County Development Plan 2022–2028, which divides the county into 2 rural area types. It lists 6 local-need categories, and describes Zone 2 — Other Rural Areas as not requiring a local-need test. A grant carries a 7-year occupancy condition (RH P2).
01 · Area types
RH P1 · RH P2 · RH P3
Applicant must satisfy Category 1 (functional economic requirement) or Category 2 (functional social requirement) in Table 3.5, plus siting/design compliance and no prior rural house in County Carlow.
RH P1 · RH P2
No local-need test; applicant must meet all Table 3.6 criteria — siting/design compliance, full-time occupation, no prior single rural house in the county, and no significant effect on the River Slaney Valley SAC from wastewater.
Map: Map 3.2 — Rural Housing Policy Zones (Section 3.16.1); confirm the site's zone on it; the engine cannot read the map.
02 · Local need
03 · Condition of permission
Occupancy as a permanent residence restricted for 7 years to the applicant/occupant who demonstrated compliance; applies in both zones.
04 · Development management
| Standard | What the plan says | Policy |
|---|---|---|
| Chapter 3 — Housing, Section 3.16 Rural Housing (Tables 3.4–3.6, RH P1–RH P17); Chapter 13 Rural Design Guide | ||
| Site size | No minimum site area stated in Chapter 3 or the Rural Design Guide; Design Guide 13.4.2 says a large house requires a large site. | |
| Ribbon development | Five or more houses along 250 metres of road frontage (per 2005 Guidelines); assessed by area type, degree of infill, coalescence with existing ribbons and local circumstances. RH P8 protects transitional lands near settlements; RH P9 discourages backland sites; RH P11 allows infill only between two fully built and occupied dwellings. | RH P10 / Section 3.16.8 |
| Sightlines | Safe entrance to TII standards without removal of extensive hedgerow or trees; sightlines per Chapter 16 development management standards (distances not retrieved). | RH P6 / Design Guide 13.4.8 |
| Access | Spatial Planning and National Roads Guidelines (2012) apply; no county-specific speed-limit rule stated in Chapter 3. | RH P6 |
| Wastewater | EPA Code of Practice (2021) for systems serving up to 10 p.e.; surface water to Carlow SuDS policy and CIRIA C753; in Zone 2 no significant adverse effect on the River Slaney Valley SAC. | RH P6 / Table 3.6(c) |
| Roadside boundary | Retain the front boundary with a simple splayed/bell-mouth opening; set-back kept to an absolute minimum and replaced like-for-like (hedgerow for hedgerow, stone wall for stone wall); overly elaborate entrances with high wing walls, pillars and gates will not be permitted. | Design Guide 13.4.7–13.4.8 |
| Replacement dwellings | Replacement of a habitable house (walls and roof intact, qualified report, recent occupation evidence) or a derelict house (structural survey, bat survey) considered without the rural housing criteria; vernacular restoration preferred over demolition. | RH P12 / RH P13 / RH P14 |
| Chapter 16 — Development Management Standards (16.10 Roads/Access, 16.11 Water Services) | ||
| Sightlines | Table 16.5 Sight Line Requirements and Distance from Edge of Carriageway — National Road 100/80 km/h: Y 210 m, X 4.5 m; Regional Road 100 km/h: Y 210 m, X 4.5 m; Regional Road 80/60 km/h: Y 150 m, X 2.5 m; Local Road 80/60 km/h: Y 90 m, X 2.5 m. Measured at driver eye height 1.05 m to object height 0.6 m. 'These are minimum standards and the Authority can request greater standards'; within built-up areas sightlines may be reduced at the planning authority's discretion. Local roads: 'Visibility splays to be stipulated at 90 metres unless a safety audit is submitted to justify a reduced sight distance' (16.10.10). | 16.10.7 / Table 16.5 / 16.10.10 |
| Entrance | 'All new entrances and junctions will require clear and unobstructed sight lines to be provided' (16.10.7; design to DMURS/TII). Minimum distance of a new rural entrance from a road junction: 150 m on National Primary, 100 m on National Secondary and Regional, 40 m on Local Primary roads (16.10.8). No gate set-back figure stated in Chapter 16; Rural Design Guide 13.4.7–13.4.8 requires a simple splayed/bell-mouth opening with set-back kept to an absolute minimum. | 16.10.7 / 16.10.8 / Design Guide 13.4.7–13.4.8 |
| Wastewater | 'For domestic dwellings site assessment and the design of waste water treatment systems and percolation areas shall conform' to the EPA Code of Practice for Domestic Waste Water Treatment Systems (2021); applications to include a detailed site investigation report with percolation and water table tests certified by a qualified person. Private wells are the householder's responsibility (16.11.2). No separation distances stated in the plan beyond the EPA Code. | 16.11.3 / 16.11.2 |
| Boundary | 'Only the minimum interference with existing roadside boundaries and hedges shall be permitted'; hedge trimming/removal for visibility must be shown on the site layout plan and third-party consent (possibly a legal agreement) is required for works outside the applicant's land (16.10.10). Design Guide 13.4.7–13.4.8: retain the front boundary, replace like-for-like (hedgerow for hedgerow, stone wall for stone wall); elaborate entrances with high wing walls, pillars and gates not permitted. | 16.10.10 / Design Guide 13.4.7–13.4.8 |
| National road access | 16.10.9 National and Regional Roads: traffic from new development to be channelled onto existing public local roads using established access points; Spatial Planning and National Roads Guidelines (DoECLG 2012) apply. | 16.10.9 |
Design guide: Chapter 13 Rural Design Guide (Carlow County Development Plan 2022–2028)
05 · Refusals
06 · Your site
The guide above is the policy. The report applies it to one site: which area type it falls in, every application nearby and how it went, flood, ground and designations, with every source linked.
07 · Source
Extracted from the adopted plan. Zones, criteria tables and RH P1–P17 read directly from the council's web text of Chapter 3; Rural Design Guide (Ch. 13) read for entrance/boundary principles.