County guides / Cavan
Cavan · county guide
Cavan's rules for one-off rural houses come from the Cavan County Development Plan 2022–2028, which divides the county into 3 rural area types. It lists 7 local-need categories, and none of the area types in the extract is described as exempt from the local-need test. A grant carries a 7-year occupancy condition (RH 06 / SUI 03 / SRA 02).
01 · Area types
SUI 01 · SUI 02 · SUI 03
Around Cavan Town and the south-east (commuting catchment of Cavan, Navan and the Greater Dublin Area). Development restricted to landowners (minimum 10 ha holding; smaller holdings case by case) and their immediate family with a demonstrable need, or rural-generated need from people intrinsic to the community. Occupancy clause of at least 7 years.
SRA 01 · SRA 02
Stable populations within town/village structures. Rural-generated, social or economic need facilitated; urban-generated need directed to towns and villages. Occupancy condition of at least 7 years.
SWA 01
Persistent population decline; largely overlap with high scenic amenity and EU designated sites (Chapter 10). Permanent residential development facilitated subject to good planning practice.
Map: Core Strategy Map (Figure 6, Chapter 1) / Appendix 21 rural area types map — confirm the site's area type; the engine cannot read the map.
02 · Local need
03 · Condition of permission
Occupancy condition of (at least) 7 years applies in Areas under Strong Urban Influence and Stronger Rural Areas; application must be in the name of the intended occupier (RH 05) with the Rural Housing Application form (RH 04).
04 · Development management
| Standard | What the plan says | Policy |
|---|---|---|
| Chapter 12 — Rural Strategy, Section 12.13 Rural Housing (12.13.2.1 Rural Area Types to 12.13.2.10) | ||
| Site size | No general minimum site area stated in Chapter 12. | |
| Ribbon development | Ribbon development where 5 or more houses exist on any one side of a given 250 metres of road frontage; proposals creating or extending it resisted, especially along radial roads from towns. | RD 01 / RH 10 |
| Sightlines | Full details of safe access/egress required; sightlines to the standards in Appendix 4; existing hedgerows retained as far as possible. | AS 01–AS 03 |
| Access | Additional access points or intensified use of existing accesses onto national roads with speed limits above 60 km/h restricted. | AS 03 |
| Wastewater | EPA Code of Practice (2009); Site Characterisation Form by a suitably qualified person; no increase in effluent loading in vulnerable clusters; concentration of septic tanks discouraged; connect to mains or group scheme where available (PW 01). | WTR 01–WTR 03 / WQG 01–WQG 09 |
| Roadside boundary | Boundaries to reflect local tradition (dry-stone or lime-mortared walls, indigenous hedging); removal of front hedgerows discouraged; evergreen non-native species not permitted; entrance gates and piers to suit rural character. | BT 01–BT 02 |
| Appendix 4 — Sightline Visibility Requirements for Junctions / Direct Accesses; Chapter 13 Development Management; Appendix 22 Design Guide | ||
| Sightlines | Appendix 4: rural roads above 60 km/h are assessed to TII DN-GEO-03060 (Table 1 rural Y distances); urban roads to DMURS 2019 (Table 2 Y distances based on stopping sight distance); Table 3 gives X distances — the tables are images in the PDF and their figures could not be read. Clear sight triangle measured from driver eye height 1.05 m to object height 1.15 m, the entire triangle to be visible. X distance measured along the access from the continuation of the public road's nearside carriageway edge (back of hard shoulder where one crosses the access); Y distance measured from the nearside edge of the main running lane to the access centreline. Use the posted speed limit; if the 85th percentile speed exceeds the limit the sightline must cover that speed (automated speed measurement may be required). Reduced sightlines may be considered on lightly trafficked local roads where 85th percentile speed is well below the limit, supported by traffic counter data, road safety audit or engineer's certification. Sightlines over third-party land need consent letters and Land Registry maps. | Appendix 4 (Tables 1–3) |
| Entrance | No gate set-back figure stated. Design Guide s.3.2 (p. 24): retain the existing front boundary where possible 'by just making a simple splayed or bell mouthed opening'; where traffic safety requires a set-back, 'always aim to re-establish what is existing'. Gates 'should be of a simple design – metal or wood and with a strong horizontal emphasis' (p. 25). Accesses must not encroach on the sightlines of neighbouring accesses or junctions in regular use (Appendix 4). | Appendix 22 s.3.2 pp. 24–25 / Appendix 4 |
| Wastewater | Chapter 13 contains no domestic wastewater standards; Design Guide application checklist (Appendix I, p. 31) requires a 'Site suitability assessment report'. Chapter 12 (rural housing) requires Site Characterisation showing suitable wastewater disposal. No separation distances stated in the plan. | Appendix 22 Appendix I p. 31 / Chapter 12 |
| Boundary | 'Hedgerows should be retained where possible'; 'Stone walls should be retained where possible' (random rubble preferred); replacement like for like (hedgerow for hedgerow, rubble for rubble); fencing timber post and rail, PVC 'not generally acceptable'; landscaping scheme must detail the entrance elevation including gates and piers. | Appendix 22 s.3.2 p. 24, pp. 23/29 |
Design guide: Design Guide for Single One-Off Houses within Cavan Rural Countryside (Appendix 22)
05 · Refusals
06 · Your site
The guide above is the policy. The report applies it to one site: which area type it falls in, every application nearby and how it went, flood, ground and designations, with every source linked.
07 · Source
Extracted from the adopted plan. Chapter 12 read directly; the extraction step flagged that some policy codes may not align perfectly with their text, so verify codes against the PDF before quoting.
Development management standards: confidence medium. Appendix 4 sightline tables are embedded images — only the method text was readable; Design Guide p. 9 sets house-size plot ratios (3/4 acre site max house 4.5%/138 sq m; 1.5 acre site max 3.0%/183 sq m) but no minimum site area.